Keating Of Chicago - 023897

Below are all the different types of Keating Of Chicago. Select the device of your choice, to download the manual


Click here to download the manual

Contents

SERVICE INSTRUCTIONS www keatingofchicago com KEATING soo E NG REQUIRED FIELD TEST BEFORE REPLACING MILLIVOLT GRIDDLE THERMOSTATS KEATING PART 037088 amp KEATING PART 023897 1 Make sure that the thermostat capillary and bulb are completely protected by the shield except for 1 not including the swedge at the end of the thermostat bulb See Note 1 2 Make sure that the thermostat shield extends to the front edge of the plate and that the capillary goes through the formed end of the shield See Note 2 3 Make sure that the bolts which hold the thermostat bulb and shield in place do not touch the thermostat bulb See Note 3 4 Make sure the capillary bulb is completely touching the bottom surface of the griddle plate DO NOT TIGHTEN THE ...